RadTarge II D300 ISO Beam Tech Code Energy (keV) Response LK55 48 82.14% LK70 60 115.72% LK100 87 98.48% LK125 109 93.51% LK170 148 96.36% 137Cs 662 100.00% 60Co 1,250 64.86% RadWall S100 ISO Beam Tech Code Energy (keV) Response LK55 48 82.14% LK70 60 115.72% LK100 87 98.48% LK125 109 93.51% LK170 148 96.36% 137Cs 662 100.00% 60Co 1,250 75.00% RadTarge II D700, RadPavise, RadWall S300 ISO Beam Tech Code Energy (keV) Response LK35 30 82.00% LK55 48 89.01% LK70 60 112.74% LK100 87 107.03% LK125 109 83.78% LK170 148 90.12% 137Cs 662 100.00% 60Co 1,250 84.82% RadTarge II
Read More
Archives for RadTarge II D700
How rugged and durable is the device?
RadTarge II, RadPavise Each face of the devices passes a drop test of 3.3 ft (1 m) onto concrete covered by a 0.16 in (4 mm) hard rubber sheet.
Read More
Why do the devices have a low upper limit on their dose rate range?
The dose rate upper limit, 1 mSv/h, is 100 mrem/h when converted to traditional units, which isn’t too low. A comparable competitor’s model, Thermo Scientific’s RadEye PRD, has an upper limit of only 25 mrem/h (250 µSv/h). Our devices’ sensitivity is very high at 340 cps/mrem/h (34 cps/μSv/h) for RadTarge II and RadPavise; as a trade-off, the upper limit on the dose rate cannot be quite as high. The next iteration of these devices, which will be available in October 2015, will have an upper limit of 10 rem/h (100 mSv/h). However, the sensitivity will not be as high as the
Read More
How much data can each device hold?
RadTarge II, RadPavise Device: 43,800 data points (5 years at 1-hour intervals) Work log (5,000 items: turn on/off time, alarm on/off time) Software: Unlimited RadWall S Device: No need for data storage; real-time air absorption dose rates and alarming Software: Unlimited
Read More
Is there a manual for the calibration procedure?
Yes; the calibration manual will be available soon.
Read More
Is calibration software available?
Yes; calibration software is available to distributors and testing labs. RadTarge II, RadPavise RadTarge II D300, RadTarge II D700, and RadPavise are calibrated using calibration software on a PC via USB. RadWall S RadWall S100 and RadWall S300 are calibrated using calibration software on a PC via IoT-Cloud.
Read More
Does my device need calibration?
Devices do not need calibration to work properly. However, depending on the rules and regulations of your industry, you may be required to regularly calibrate your equipment for quality assurance purposes.
Read More
How long does it take to charge the battery?
Turn off the device to charge it faster. RadTarge II RadTarge II D300 and D700 need 2 hours to fully charge. When the device is charging, the red light will turn on. After it is fully charged, the red light will turn off. RadPavise RadPavise needs 3–4 hours to fully charge. When the device is charging, the green light will turn on. After it is fully charged, the green light will turn off.
Read More
Is the reading still accurate with a low battery?
Yes; when the battery is running low, the measurement is still accurate.
Read More
How can I tell if the battery is low?
RadTarge II, RadPavise The battery indicator on the screen shows the remaining charge on the battery. After running out of battery, the device continues to work for 4 hours. After 4 hours, the battery indicator flashes for 6 seconds before the device shuts down. RadWall S If there is no external power source, RadWall S will continue to run on its backup battery for 10 hours.
Read More