The Detector Module is based on YSO and SiPM, which can be used for Gamma counting or energy measurements. Compared to traditional radiation detectors, our Detector Modules have many advantages: compact and light design, low power consumption, temperature and magnetic field stability, on-demand size, and competitive pricing.
Features
- Gamma counting and energy measurements
- High sensitivity from density of the detection crystal
- Compact and light design
- Temperature stability
- Magnetic field stability
- Low voltage power supply and consumption
- On-demand size
- Very competitive price
Physical Characteristics
- Energy range for gamma counting: 20 keV–3 MeV
- Energy range for energy measurements: 30 kev–1.33 MeV
- Energy resolution: < 10% @ 662 keV
Electrical Characteristics
- Power supply: 30±2 V DC
- Power consumption: < 0.1 mA
Environmental Characteristics
- Operating temperature: 32–140 °F (0–60 °C)
- Storage temperature: -4–140 °F (-20–60 °C)
- EMC compliance: exceeds standards by a large margin
Functional Characteristics
- One connector: pick-and-placeable u.FL connector
Customization
- YSO 0.16 x 0.16 x 0.83 in (4.06 x 4.06 x 21.08 mm)
SiPM 0.16 x 0.16 in (4.06 x 4.06 mm) - YSO 0.28 x 0.28 x 0.83 in (7.11 x 7.11 x 21.08 mm)
SiPM 0.28 x 0.28 in (7.11 x 7.11 mm)
Real Life Examples
- For radiation detection instruments:
- Dosimeter
- Personal radiation detector
- Survey meter
- Area monitor
- For medical use:
- Gamma counter
- For industry use:
- Nuclear density gauge
- Non-destructive assay (NDA)
- For security use:
- Radiation portal for pedestrian, vehicle, and cargo monitoring
- Embedded in a metal detection unit
Voltage Supply and Readout Module | Radiation Detection Modules
The Voltage Supply and Readout Module is the smallest regulated DC-DC high-voltage power supply for SiPM. It also converts the charge or current signal from the SiPM into a voltage that can be readily processed by DAQ.
Features
- Extra-small and lightweight
- Battery or DC input from 2–5 V
- Low ripple (< 50 mV peak to peak)
- Remarkably short signal duration
- Exceptionally high count rate
Physical Characteristics
- Pulse duration: < 1 μs
- Count rate: < 106 cps
Electrical Characteristics
- DC Input : 2–5 V
- Power consumption: < 2 mA (with Detector Module)
Mechanical Characteristics
- Dimensions: 0.79 x 0.79 in (20.07 x 20.07 mm)
Environmental Characteristics
- Operating temperature: 32–140 °F (0–60 °C)
- Storage Temperature: -4–140 °F (-20–60 °C)
- EMC compliance: exceeds standards by a large margin
Functional Characteristics
- Three connectors:
- One U.FL connector for connection to detect module
- One U.FL connector for connection to DAQ
- One two-pin connector for connection to battery
Real Life Examples
- For radiation detection instruments:
- Dosimeter
- Personal radiation detector
- Survey meter
- Area monitor
- For medical use:
- Gamma counter
- For industry use:
- Nuclear density gauge
- Non-destructive assay (NDA)
- For security use:
- Radiation portal for pedestrian, vehicle, and cargo monitoring
- Embedded in a metal detection unit
DAQ Module | Radiation Detection Modules
Coming Soon
We will provide DAQ modules based on our patented MVT technology and DAQ modules based on ADC.